background image

Chapter 7 – Prestart Inspection

TB42/TB50 – 0074923

37

Danger

Pinch points may exist between moving components.

Death or serious injury will result from becoming

trapped between components. Make sure all person-

nel stand clear while lowering the platform with the

emergency lowering knob.

3. Make sure there is nothing in the way to obstruct

the platform when it lowers.

4. Slowly turn the emergency lowering knob to open

the bleed down valve (refer to Figure 7.13). The

boom should slowly lower.

Figure 7.13 – Emergency Lowering Knob

5. Turn the knob to close the cylinder bleed down

valve.

Warning

The potential for an accident increases when safety

devices do not function properly. Death or serious

injury could result from such accidents. Fully close

the emergency lowering valve before operating the

aerial platform.

6. Make certain the emergency lowering valve is fully

closed before operating the aerial platform.

Level Sensor

Use the following procedure to test the level sensor.

1. Position the aerial platform on a smooth, flat, level

surface.

2. Remove all persons and materials from the plat-

form.

3. Start the engine and raise the main boom above

horizontal, approximately 15 to 20 degrees.

4. Open the rear door on the left side of the machine

to access the level sensor (refer to Figure 7.14).

Figure 7.14 – Level Sensor

5. Pull the level sensor to the side as far as possible

to activate the tilt alarm.

Warning

The potential for an accident increases when safety

devices do not function properly. Death or serious

injury can result from such accidents. Do not alter,

disable, or override any safety device.

6. If the alarm does not sound, remove the machine

from service until the problem is corrected.

7. Lower the main boom.

Flashing Light

The machine may be equipped with an optional flashing

light mounted on top of the cowling on each side of the

machine (refer to Figure 7.15).

Figure 7.15 – Flashing Light

To inspect the flashing lights:

1. Turn the battery disconnect on, pull the emergency

stop button outward at the lower controls, and turn

the start switch on.

2. Visually check to see that the light is flashing ap-

proximately one flash per second.