beautypg.com

Chapter 6 – controls, Battery disconnect switch, Lower controls – Snorkel TB50 User Manual

Page 27: Emergency stop button, Control selector switch, Start switch, Chapter 6 – controls danger, Caution

background image

TB42/TB50 – 0074923

23

The following are located on the lower control panel.

• Emergency stop button

• Control selector switch

• Start switch

• Ground operation switch

• Rotation switch

• Boom elevation switch

• Boom extend/retract switch

• Boom speed knob

• Platform level switch

• Platform rotation switch

• Engine/emergency power switch

• Throttle switch

• Fuel switch (dual fuel machines)

Emergency Stop Button

The emergency stop button (refer to Figure 6.2) is a

two-position, red push button.

Push the button inward to disconnect power to all

control circuits.

Pull the button outward to restore power.

On older machines, the emergency stop is a two-position

toggle switch with a red safety guard.

Push the guard down over the toggle switch to dis-

connect power to all control circuits

Lift the guard and push the toggle switch up to re-

store power.

Control Selector Switch

Use the control selector switch (refer to Figure 6.2)

to select between the lower control and upper control

operation.

Push the switch upward to operate the aerial platform

from the upper controls.

Push the switch downward to operate the aerial

platform from the lower controls.

Start Switch

The start switch (refer to Figure 6.2) works like an au-

tomobile ignition switch.

Hold the switch in the start position until the engine

starts, then release it to on.

If the engine dies, the switch must be turned to off

before it can be turned back to start.

An alarm sounds, when the switch is turned on, to warn

others that the machine engine is being started.

Chapter 6 – Controls

Danger

Pinch points may exist between moving compo-

nents. Death or serious injury can result from being

trapped between components, buildings, structures,

or other obstacles. Make sure all personnel stand

clear while operating the aerial platform.

Controls to position the platform are located on the

lower control panel on the turntable and on the upper

control panel in the platform.

Controls to drive the aerial platform are located on

the upper control panel only.

Battery Disconnect Switch

The battery disconnect is located behind the door on

the left side of the turntable above the batteries (refer

to Figure 6.1).

Figure 6.1 – Battery Disconnect Switch

The battery disconnect removes electrical power from all

electrically controlled functions when in the off position.

Place the switch in the on position to electrically

connect the battery to the electrical system.

Caution

Only authorized personnel should operate the aerial

platform. Unqualified personnel may cause injury

to coworkers or property damage. Lock the battery

disconnect switch in the off position before leaving

the aerial platform unattended.

Turn the battery disconnect switch off to prevent

unauthorized use of the aerial platform.

Lower Controls

The lower controls (refer to Figure 6.2) are located on the

right side of the turntable. Boom and platform functions

can be operated from the lower controls.

Battery Disconnect Switch

This manual is related to the following products: