background image

32

DRIVE Disabled

LIFT DOWN Disabled

Drive Speed Cup-Back (Turtle) Mode

Engaged (When Platform is Elevated)

LIFT UP Disabled

Both LIFT UP and LIFT DOWN Disabled

Battery Charger (AC) Plugged In

- +

LCD Display Fault Conditions
Table 3-3, LCD Display – Operating Fault Conditions show common LCD display Fault

indications which may occur during operation and are usually caused by either an error in

machine operation or a work area condition. These fault conditions can usually be corrected

by the operator and do not require a qualified mechanic to repair.

IMPORTANT

AFTER A FAULT CONDITION IS CORRECTED THE MACHINE POWER MAY NEED TO
BE RECYCLED TO RESET THE GROUND CONTROL STATION.

Table 3-3. LCD Display – Operating Fault Conditions

FAULT

CODE

PLATFORM

CONSOLE

LED FAULT

CODE

LCD SYMBOL SCREEN

LCD TEXT

SCREEN

FAULT

DESCRIPTION/

MACHINE

CONDITION

LOOK FOR THIS

_

_

Brakes Released

(DRIVE

Disabled)

To Engage

Brakes-Press

Brake Release

Button on Ground

Control Station

BRAKES RELEASED

+

-

00000.0