Fluid Management Miller GyroMixer User Manual
Page 32
![background image](/manuals/545206/32/background.png)
SERVICE
28
REASSEMBLING THE MOTOR
1.
Remove the key taped to the side of the new motor.
2.
Slide the motor drive pulley onto the shaft and into the same position
measured during removal in Step 9, REMOVING THE MOTOR.
3.
Place the key inside the keyway in the motor drive pulley and tighten the
set screw. The key should be seated in the driveshaft keyway. It should
be positioned in the same way as on the old motor (as noted in Step 9,
REMOVING THE MOTOR).
4.
Push the circular retaining ring into the motor pulley.
5.
Viewing the shaft end of the motor, confirm that the rotation of the
motor is CW (clockwise). Refer to the diagram on the side of the motor
for a detailed wiring diagram.
6.
Lift the motor, with the wires pointing downward, into position and
fasten to the motor mounting bracket with the four (4) screws.
7.
Before completely tightening the screws, manually turn the rotating
mechanism one full revolution to verify that the motor does not interfere
with the rotating mechanism.
Note:
If there is interference, move the motor slightly to correct
the problem before tightening the screws.
8.
Connect L1, L2, and ground wires to the motor. Refer to the diagram on
the side of the motor to verify the motor wiring for clockwise rotation as
viewed from the shaft end.
9.
Reassemble the tubing connector nut onto the conduit box.
10.
Close the motor cover plate with the screw.