Fluid Management Miller GyroMixer User Manual
Page 20

MAINTENANCE
16
SEMI-ANNUALLY
•
Test the secondary drive V-belt tension. Adjust, if necessary, to proper
tension (approximately 7 lbs to deflect the belt 1/4”).
•
Check the secondary drive V-belt for wear or damage. Replace if
necessary.
•
Remove the rear access panel. Test the primary drive poly V-belt
tension. Adjust, if necessary to proper tension (approximately 4-5 lbs to
deflect the belt 3/8”).
•
Check the primary drive poly V-belt for wear or damage. Replace, if
necessary.
•
Check clamping force.
- Load a container into the mixer
- Fully clamp the container into position.
- Attempt to move the container.
- If the container moves, adjusts the clamping force by tightening the
nut on the handle. Refer to the Service section for further instructions.
•
Spray silicone in the door tracks for smooth operation.
•
Inspect the door lock linkage for tightness. Refer to the Service section.