Installing the assembly – Hale RSD User Manual
Page 75
75
RSD Series Single-Stage PTO Pumps
p/n: 029-0020-92-0
Co rr ec tive M ain te n an ce
❑
8.
Carefully remove the assembly from the apparatus.
9.
Move the pump assembly to a clean work area and clamp into a suitable
and stable holding device being careful not to damage any sealing
surfaces.
Installing the Assembly
After completing repairs and/or maintenance, install the pump assembly to
the apparatus before filling with oil.
1.
First, review preceding Section “Before You Begin...” on page 67.
2.
Attach proper supporting devices and stabilize the assembly for trans-
port to the apparatus. Also see WARNING ! note found on page 68.
3.
Place the pump assembly into position within the apparatus.
4.
Apply Loctite and insert and tighten mounting hardware that secures the
pump assembly to the chassis frame. Torque the fasteners to proper val-
ues in accordance with manufacturer’s recommendations. Also see
Table 6-1: “Typical Torque Values Chart” on page 69.
5.
With the pump assembly secured to the apparatus, remove the lifting
device.
6.
Connect the drive shaft to the gearbox. Apply a coating of Loctite to the
fasteners and torque to the PTO manufacturer’s specifications.
7.
Connect all components to the gearbox. Then fill the gearbox to the
proper oil level. See Section 4: Preventive Maintenance, heading
“Replace Gearbox Oil” on page 52.
8.
Reassemble and connect all components removed to gain access to the
pump assembly, paying particular attention to your sketch (photographs)
and identification match markings/tags (e.g., valves, suction piping, dis-
charge piping, valve operators, etc.)
9.
Reinstall apparatus frame work and body panels previously removed to
gain access to the pump compartment.
10.
Test the pump for proper operation per your departmental requirements.
Note and repair any leaks.
11.
Recheck and top off oil levels, then return the apparatus to operation.