2a.2 auxiliary cooling, 2a.3 pressure and relief valve control, P series relief valve system – Hale RSD User Manual
Page 22
❑ Accessories
22
Section 2a: Accessories
Hale Products, Inc., Nov. 2005, Rev-A
Typically, three (3) are used. Anodes can be mounted in any position, hori-
zontal or vertical. Anodes should be inspected periodically * and replaced
when over 75% of the metal has been consumed. Performance of the
anode varies with water quality and PH.
* Zinc anodes should be inspected every twelve (12) months. Magnesium
anodes, which are consumed at a faster rate, should be inspected ever three (3)
or four (4) months.
2A.2 AUXILIARY COOLING
For pumps not equipped with standard gearbox cooling, a cooler option is
available to protect the gearbox, the apparatus engine, and the pump. The
gearbox cooler circulates pump water to transfer heat from the gearbox oil
to the pump discharge, thus maintaining proper operating temperatures.
2A.3 PRESSURE AND RELIEF VALVE CONTROL
Note: For additional information about the pressure and relief valves in your sys-
tem, also see the separate manual provided with the valves.
P Series Relief Valve System
Figure 2a-2: P Series Relief Valve System Arrangement