Management module removal and replacement, Time and items required, Faulty management module indicators – Brocade Communications Systems Brocade VDX 8770-4 User Manual
Page 72: Recording critical brocade vdx 8770-4 information

52
Brocade VDX 8770-4 Hardware Reference Manual
53-1002563-02
Management module removal and replacement
5
6. Slide the line card all the way into the slot.
7. Close the ejectors by rotating them away from the center of the line card. The levering action of
the ejectors seats the line card in the slot.
8. Tighten the captive screws using the Phillips screwdriver.
Management module removal and replacement
This section describes how to remove and replace a management module (MM). Each Brocade VDX
8770-4 chassis can have one or two management modules. They reside in slots M1 and M2. There
must be at least one MM installed for the chassis to operate.
Time and items required
The replacement procedure for the MM takes approximately 30 minutes. The following items are
required for the MM replacement:
•
ESD grounding strap
•
Workstation computer
•
Serial cable
•
IP address of an FTP server for backing up the Brocade VDX 8770-4 configuration
•
#2 Phillips screwdriver
•
Replacement management module
Faulty management module indicators
Confirm that you need to replace the management module. The following events might indicate
that a management module is faulty:
•
The status LED on the management module is lit steady amber, or the power LED is not lit.
•
The management module does not respond to Telnet commands, or the serial console is not
available.
•
The show mm command does not show that the management module is enabled.
•
Additional information from the show mm command indicates a problem.
•
The clock is inaccurate, or the management module does not boot up or shut down normally.
For more information about error messages, refer to the Network OS Message Reference.
Recording critical Brocade VDX 8770-4 information
Back up the chassis configuration before you replace a management module. Refer to
on page 30 for backup information.