Determining the status of a management module, Figure 7, Manageme – Brocade Communications Systems Brocade VDX 8770-4 User Manual
Page 60: Table 10

40
Brocade VDX 8770-4 Hardware Reference Manual
53-1002563-02
Determining the status of a management module
4
Determining the status of a management module
You must have at least one management module (MM) active for the chassis to be functional. For
redundancy, you need two MMs. The active MM is designated by the blue Active LED on the front
panel.
Complete the following steps to determine the status of a MM.
1. Check the LED indicators on the module (
). The LED patterns may temporarily change
during POST and other diagnostic tests. For information about how to interpret the LED
patterns, refer to
2. You can use the show mm command to see whether the management modules are enabled.
You can also run the show interface management 1/1 to see the configuration information.
identifies the management module.
FIGURE 7
Management module
describes the management module LED patterns and the recommended actions for those
patterns.
1
Status LED
5
Ethernet port (Mgmt IP)
2
Power LED
6
USB port
3
Active LED
7
Ethernet port (Service IP)
4
Console port (Serial)
TABLE 10
Management module LED descriptions
LED purpose
Color
Status
Recommended action
Power
Steady green
MM
is powered on.
No action required.
No light (LED is off)
MM
is not powered on.
Ensure that the module is firmly
seated and has power.
Status
No light (LED is off)
MM
is either healthy or does
not have power.
Verify that the power LED is on.
Steady amber
MM
requires attention or is
still booting up.
If the LED remains amber, the
module is faulty. Consult the
Brocade VDX 8770-4 supplier.
2
4
7
5
6
3
1