Table 10—Evaporator-Fan Motor Data — Standard Motor

UNIT

551B

551C

UNIT

PHASE

MAXIMUM

CONTINUOUS BHP*

MAXIMUM

OPERATING WATTS*

UNIT VOLTAGE

MAXIMUM

AMP DRAW

024

ALL

0.58

580

2.0

75.0

Single

1.20

1000

208/230

4.9

036

208/230

4.9

036

Three

1.20

1000

460

2.2

Three

1.20

1000

575

2.2

Single

1.20

1000

208/230

4.9

048

208/230

4.9

048

Three

1.20

1000

460

2.2

Three

1.20

1000

575

2.2

Single

1.30

1455

208/230

7.0

060

208/230

6.7

060

Three

2.40

2120

460

3.0

Three

2.40

2120

575

3.0

208/230

6.7

072

Three

2.40

2120

460

3.0

072

Three

2.40

2120

575

3.0

LEGEND

Bhp — Brake Horsepower

*Extensive motor and electrical testing on these units ensures that the full horsepower and watts range of the motors can be utilized with confidence. Using the

fan motors up to the ratings shown in this table will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected.

Table 11—Evaporator-Fan Motor Data — High-Static Motors

UNIT

551B

551C

UNIT

PHASE

MAXIMUM

CONTINUOUS BHP*

MAXIMUM

OPERATING WATTS*

UNIT VOLTAGE

MAXIMUM

AMP DRAW

208/230

6.7

036

Three

2.40

2120

460

3.0

036

Three

2.40

2120

575

3.0

208/230

6.7

048

Three

2.40

2120

460

3.0

048

Three

2.40

2120

575

3.0

208/230

8.6

060

Three

2.90

2615

460

3.9

060

Three

2.90

2615

575

3.9

208/230

8.6

072

Three

2.90

2615

460

3.9

072

Three

2.90

2615

575

3.9

LEGEND

Bhp — Brake Horsepower

*Extensive motor and electrical testing on these units ensures that the full horsepower and watts range of the motors can be utilized with confidence. Using the

fan motors up to the ratings shown in this table will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected.

Table 12—Accessory/FIOP Electric Heaters Static Pressure Drop (in. wg) — 551B 036--072 and 551C 024--060

COMPONENT

CFM

COMPONENT

600

900

1200

1400

1600

1800

2000

2200

2400

2600

1 Heater Module

0.03

0.05

0.07

0.09

0.09

0.10

0.11

0.11

0.12

0.13

2 Heater Modules

0.14

0.15

0.16

0.16

0.16

0.17

0.17

0.17

0.18

0.18

Table 13—Accessory/FIOP EconoMi$er IV and EconoMi$er2 Static Pressure* (in. wg) — 551B 036--072 and 551C 024--060

COMPONENT

CFM

COMPONENT

600

800

1000

1250

1500

1750

2000

2250

2500

2750

3000

Vertical EconoMi$er IV

0.01

0.02

0.035

0.045

0.065

0.08

0.12

0.145

0.175

0.22

0.255

Horizontal EconoMi$er IV

---

---

---

0.1

0.125

0.15

0.18

0.225

0.275

LEGEND

FIOP --- Factory---Installed Option

*The static pressure must be added to external static pressure. The sum and the indoor entering-air cfm should be used in conjunction with the Fan Performance

tables to determine indoor blower rpm and watts.