beautypg.com

Agilent Technologies 6631B User Manual

Page 75

background image

Language Dictionary - 4

75

TRIGger:SEQuence2:COUNt:CURRent
TRIGger:ACQuire:COUNt:CURRent

Agilent 66312A, 66332A Only

This command sets up a successive number of triggers for measuring current data. With this command,
the trigger system needs to be initialized only once at the start of the acquisition period. After each
completed measurement, the instrument waits for the next valid trigger condition to start another
measurement. This continues until the count has completed.

Command Syntax

TRIGger:SEQuence2:COUNt:CURRent
TRIGger:ACQuire:COUNt:CURRent

Parameters

1 to 100

*RST Value

1

Examples

TRIG:SEQ2:COUN:CURR 5 TRIG:ACQ:COUN:CURR 1

Query Syntax

TRIGger:SEQuence2:COUNt:CURRent?
TRIGger:ACQuire:COUNt:CURRent?

Returned Parameters

Related Commands

TRIG:SEQ2 TRIG:ACQ

TRIGger:SEQuence2:COUNt:VOLTage
TRIGger:ACQuire:COUNt:VOLTage

Agilent 66312A, 66332A Only

This command sets up a successive number of triggers for measuring voltage data. With this command,
the trigger system needs to be initialized only once at the start of the acquisition period. After each
completed measurement, the instrument waits for the next valid trigger condition to start another
measurement. This continues until the count has completed.

Command Syntax

TRIGger:SEQuence2:COUNt:VOLTage
TRIGger:ACQuire:COUNt:VOLTage

Parameters

1 to 100

*RST Value

1

Examples

TRIG:SEQ2:COUN:VOLT 5 TRIG:ACQ:COUN:VOLT 1

Query Syntax

TRIGger:SEQuence2:COUNt:VOLTage?
TRIGger:ACQuire:COUNt:VOLTage?

Returned Parameters

Related Commands

TRIG:SEQ2 TRIG:ACQ

This manual is related to the following products: