Replacing the hot-swap-drive backplane – Lenovo ThinkServer TD350 User Manual
Page 162
11. Position the new AnyRAID adapter or the pass-through board near the backplane. Then, carefully press
the new AnyRAID adapter or the pass-through board straight into the AnyRAID-adapter slots until it
is securely seated. Tighten the two screws to secure the new AnyRAID adapter or the pass-through
board in place.
Figure 114. Installing the AnyRAID adapter or the pass-through board
12. Reinstall the AnyRAID-adapter air duct (if available).
13. Reconnect the cables. See “Connecting cables” on page 39.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the replacement procedure, go to “Completing the parts replacement” on page 164.
Replacing the hot-swap-drive backplane
Attention: Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 63.
This topic applies only to server models that have hot-swap internal storage drives installed.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Notes:
• The hot-swap-drive backplane is sensitive to ESD. Ensure that you read and understand “Handling
static-sensitive devices” on page 64 first and carefully perform the operation.
• Depending on the model, your server might look slightly different from the illustrations in this topic.
• Use any documentation that comes with the new hot-swap-drive backplane and follow those instructions
in addition to the instructions in this topic.
To replace the hot-swap-drive backplane, do the following:
148
ThinkServer TD350 User Guide and Hardware Maintenance Manual