beautypg.com

Room sub control unit (is-rcu), Part names, Specifi cations – Aiphone IS SERIES 834168 C P0811JZ User Manual

Page 14

background image

14

Room sub control unit (IS-RCU)

Part names

NOTE:
The illustration of the unit may differ from the actual one.

Specifi cations

Room sub control unit (IS-RCU)

Power source

48V DC (supplied from the power supply unit)

Current consumption

Max. 1.8A

Ambient temperature

0 - 40°C (+32°F - +104°F)

Talk channels

Local system: 2 talk channels, 1 chime

Audio door station(s)
Room sub station(s)

Max. 30

Mounting

Rack-mount (19-inch, 2U rack) or wall-mount

Material

Steel plate

Color

Black

CONTACT OUTPUT terminals

PA (Paging) OUTPUT terminals

AUDIO DOOR/SUB STATION ports

Central control unit (IS-CCU) /
IP control unit (IS-IPC) ports

ID setting switch
(→P.15)

POWER terminals

POWER switch
Turns the power ON ( ) or OFF ( ).

POWER LED (green)
Lights up when the power is ON.

STATUS LED (green)
Blinks when this unit is initialized or an error*

1

occurs.
The LED will light up when this unit returns to
the normal state.
*

1

: Communication error in a unit connected

to this unit, or between this unit and a unit
connected to it, etc.