Digital filter characteristics, Dc electrical characteristics, Cs8421 – Cirrus Logic CS8421 User Manual
Page 11: Cs8421 digital filter characteristics

DS641F6
11
CS8421
CS8421
DIGITAL FILTER CHARACTERISTICS
3.
The equation for the group delay through the sample-rate converter is (56.581 / Fsi) + (55.658 / Fso). For example,
if the input sample rate is 192 kHz and the output sample rate is 96 kHz, the group delay through the sample-rate
converter is (56.581/192,000) + (55.658/96,000) =.875 milliseconds.
DC ELECTRICAL CHARACTERISTICS
(GND = 0 V; all voltages with respect to 0 V.)
4.
Power Down Mode is defined as RST = LOW with all clocks and data lines held static, except when a crystal is
attached across XTI-XTO, in which case the crystal will begin oscillating.
5.
Normal operation is defined as RST = HI.
Parameter
Min Typ
Max
Units
Passband (Upsampling or Downsampling)
-
-
0.4535*Fso
Hz
Passband Ripple
-
-
±0.007
dB
Stopband
0.5465*Fso
-
-
Hz
Stopband Attenuation
125
-
-
dB
Group Delay
SRC Mode
Bypass Mode
-
-
-
-
3/Fsi
s
s
Parameter Symbol
Min
Typ
Max
Units
Power-Down Mode
Supply Current in power-down
VD
(Oscillator attached to XTI-XTO)
VL = 3.3 V
VL = 5.0 V
50
100
200
A
A
A
Supply Current in power-down
VD
(Crystal attached to XTI-XTO)
VL = 3.3 V
VL = 5.0 V
100
1.5
4
A
mA
mA
Normal Operation
Supply Current at 48 kHz Fsi and Fso
VD
(Oscillator attached to XTI-XTO)
VL = 3.3 V
VL = 5.0 V
24
2.5
4
mA
mA
mA
Supply Current at 192 kHz Fsi and Fso
VD
(Oscillator attached to XTI-XTO)
VL = 3.3 V
VL = 5.0 V
80
8
13
mA
mA
mA
Supply Current at 48 kHz Fsi and Fso
VD
(Crystal attached to XTI-XTO)
VL = 3.3 V
VL = 5.0 V
24
3
7
mA
mA
mA
Supply Current at 192 kHz Fsi and Fso
VD
(Crystal attached to XTI-XTO)
VL = 3.3 V
VL = 5.0 V
80
4
6.5
mA
mA
mA