Hand Spindle Pump

CPP1000-M/-L

WIKA Operating Instructions Hand Spindle Pump

18

If the blind plug is removed completely, a small

cylindrical body, made of red plastic, is visible.

This plastic body is to reduce the internal volume

of the pump if a shut-off valve or fine adjustment

valve is not used / mounted.

Remove the red cylindrical body using tweezers

or blow it out through the open test connection

using compressed air.

Now screw in the shut-off valve or the fine adjust-

ment valve.

Pull tight the valve using a flat wrench 27 mm.

This parts are left over and may be depolluted:

blind plug

red cylindrical body