Gb 3. technical data – WIKA PGT43.100 User Manual
Page 7

GB
3. Technical data
3.4 Model PGT23.100 / PGT23.160
Working pressure
- Steady
Full scale range
- Fluctuating
0.9 x full scale range
- Transient
1. x full scale range
Temperature influence
max. ± 0.4 % of full scale range/10 K (when the temperature of the
measuring system deviates from +0 °C reference temperature)
IP protection class
- Housing
IP 54 per EN 60 59 / IEC 60 59
- With liquid filling
IP 65
Permissible temperatures
- Ambient
filled/unfilled -40 ... +60 °C
- Medium
maximum +100 °C
Further technical data see data sheet PV 1.04
3.5 Model PGT43.100 / PGT43.160
Working pressure
- Steady
Full scale range
- Fluctuating
0.9 x full scale range
- Transient
5 x full scale range, however max. 40 bar
Temperature influence
max. ± 0.8 % of full scale range/10 K (when the temperature of the
measuring system deviates from +0 °C reference temperature)
IP protection class
- Housing
IP 54 per EN 60 59 / IEC 60 59
- With liquid filling
IP 65
Permissible temperatures
- Ambient
filled/unfilled -0 ... +60 °C
- Medium
maximum +100 °C
Further technical data see data sheet PV 14.0
3.6 Model PGT43HP.100 / PGT43HP.160
Working pressure
- Steady
Full scale range
- Fluctuating
0.9 x full scale range
- Overload capability
40, 100 and 400 bar
Temperature influence
max. ± 0.8 % of full scale range/10 K (when the temperature of the
measuring system deviates from +0 °C reference temperature)
IP protection class
- Housing
IP 54 per EN 60 59 / IEC 60 59
- With liquid filling
IP 65
Permissible temperatures
- Ambient
filled/unfilled -0 ... +60 °C
- Medium
maximum +100 °C
Further technical data see data sheet PV 14.07
11
97
64 05/
009 GB/D/F/E
WIKA Operating Instructions intelliGAUGE family
7