1 setting the machine, Setting the machine, Table 2: dip-switch definitions – Kramer Electronics VS-81SP User Manual
Page 14: Table 3: machine # dip-switch settings, Table 2, Table 3, Connecting the vs-81sp 8 x 1 loudspeaker switcher, 11 table 2: dip-switch definitions
Connecting the VS-81SP 8 x 1 Loudspeaker Switcher
11
11
Table 2: DIP-switch Definitions
DIP
Function:
1-4
Set the MACHINE # (see section
5-7
MACHINE ADDRESS # in daisy chain connection (see section
8
Last cascaded device
9-11 (marked 1-3 on second set) Firmware upgrade (see section
12 (marked 4 on second set)
RS-485 termination (see section
6.3.1 Setting the MACHINE #
To control a unit via RS-232 or RS-485, each unit has to be identified by its
unique MACHINE #. Set the MACHINE # on a VS-81SP unit according to
. A valid MACHINE # is from 1 to 15. For a single, stand-alone
machine, set as MACHINE # 1.
Table 3: MACHINE # DIP-switch Settings
MACHINE #
DIP 1
DIP 2
DIP 3
DIP 4
1
ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
ON
ON
OFF
OFF
4
OFF
OFF
ON
OFF
5
ON
OFF
ON
OFF
6
OFF
ON
ON
OFF
7
ON
ON
ON
OFF
8
OFF
OFF
OFF
ON
9
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
illustrates how to set the DIP-switches on four single VS-81SP
units, which are controlled by one RS-232 port: