beautypg.com

11 table of hex codes for serial communication, Table of hex codes for serial communication – Kramer Electronics VS-44HC User Manual

Page 40

background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Table of Hex Codes for Serial Communication

36

11 Table of Hex Codes for Serial Communication

Sections 11.1 and 11.2 contain the tables of hex codes for switching and

setting the delay time, respectively.

11.1

Hex Codes for Switching

Table 14 lists the Hex values for a single machine (machine # 1):

Table 14: VS-44HC Hex Codes for Switching via RS-232/RS-485

Switching Video Channels

Switching Audio Channels

OUT 1

OUT 2

OUT 3

OUT 4

OUT 1

OUT 2

OUT 3

OUT 4

IN 1

3

4

2

2

2

3

2

4

IN 2

3

4

2

2

2

3

2

4

IN 3

3

4

2

2

2

3

2

4

IN 4

3

4

2

2

2

3

2

4

11.2

VS-44HC Hex Codes for Setting the Audio Delay Time

To set the audio delay time, use command 22 (set audio parameter) in the

following way:

Byte 1 should be 22 (16H)
Byte 2 should be 127 (80H) plus input Channel number (from 1 to 4)
Byte 3 should be 127 (80H) plus delay value in milliseconds (from 1 to

127)

Byte 4 should be 127 (80H) plus machine number (from 1 to 15)

Table 15 describes several examples for the hex codes used to set the delay

time:

Table 15: VS-44HC Hex Codes for Setting the Audio Delay Time

Delay Time

[msec]

For

Command

0

IN 1

I6

81

80

81

5

IN 2

I6

82

85

81

64

IN 3

I6

83

84

81

127

IN 4

I6

84

FF

81