1 the tp-121 internal polarity switches, 2 your tp122 xga/audio line receiver, 1 your tp122 xga/audio line receiver (topside) – Kramer Electronics TP-124 User Manual
Page 13: The tp-121 internal polarity switches, Your tp-122 xga/audio line receiver, Your tp-122 xga/audio line receiver (topside), Figure 6: tp-121 internal polarity switches
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Your TP-121/TP-122
10
6.1.1 The TP-121 Internal Polarity Switches
define the internal sync polarity switches inside the
TP-121.
Note, that you need to open the TP-121 unit to gain access to the Vs and Hs
Polarity switches. After setting the switches, close the TP-121 unit.
Figure 6: TP-121 Internal Polarity Switches
Table 5: Features of the TP-121 Internal Polarity Switches
Feature
Function
VS Switch
Slide the switch down
, to set the V SYNC to negative polarity (NEG.);
slide the switch up, to set the V SYNC to its input polarity (NORM.)
HS Switch
Slide the switch down
6.2 Your TP-122 XGA/Audio Line Receiver
, to set the H SYNC to negative polarity (NEG.);
slide the switch up, to set the H SYNC to its input polarity (NORM.)
This section describes the topside (see section
), and the underside
) of the TP-122 XGA/Audio Line Receiver.
6.2.1 Your TP-122 XGA/Audio Line Receiver (Topside)
The TP-122 is an XGA/audio line receiver that receives the coded CAT 5
signal transmitted by a TP-121, decodes it and converts it to XGA, stereo
analog and S/PDIF digital audio outputs. The TP-122, with a TP-121,
allows an operation range of more than 300ft (more than 100m) over
standard CAT 5 cable.
1 By default, both switches are set down (for a negative V SYNC and H SYNC polarity)
2 The underside is identical on the TP-122 and TP-124
NORM.
NEG.