9 diagnosis and error treatment, 10 technical specifications, 9diagnosis and error treatment – Festo Шаговые моторы MTRE-ST User Manual
Page 44

MTRE−ST42−48S−..
Festo MTRE−ST42−48S−.. 0503b English
44
9
Diagnosis and error treatment
Fault
Cause
Possibilities
Motor does not
move
Motor cable defective
Check motor cable
move
Brake not activated
Open brake by applying 24ĂV DC
Supply voltage is below 21 V DC
or above 51 V DC
Measure supply voltage
Motor loses
steps
Motor cannot give torque
required
Check characteristic curve of
motor, check which torque can
be given
Frequency too high
Reduce frequency (controller)
10
Technical specifications
Motor
MTRE−ST42−48S−A A
MTRE−ST42−48S−AB
Rated voltage
24 ... 48 V DC +5/−10 %
Current setting
0.3 ... 1.2 A (Steps of 0.2 A)
Holding torque M
0.34 Nm
Step angle
ö
1.8°
±5 %
Moment of inertia of drive J
0.068 kg cm
2
0.07 kg cm
2
Holding torque of brake M
ć
0.4 Nm
Output of brake P
ć
6 W
Voltage of brake V
ć
24 V
Radial shaft load N
18 N
18 N
Axial schaft load N
7 N
7 N
Weight of product m
0.45 kg
0.55 kg