2. Parameters of the SPC11 for the DNCI or DDPC

2-5

Festo P.BE-SPC11-DNCI-EN en 1208a English

2.2

Setting parameters A, C and S

Warning
Incorrectly set parameters can damage the fixed stops and
the drive.

Be very careful when setting the parameters.

Always select the amplification and cushioning stages
for the maximum mass load. In case of doubt, set first
the amplification and cushioning stages for the larger
mass load.

The positioning times specified in section 2.3 as well as opti-
mum system behaviour can only be achieved if the installa-
tion instructions described in the previous section are ob-
served. The resulting positioning times depend on the stroke
length actually used and can vary depending on the direction
of stroke. Further instructions on the amplification and
cushioning stages can be found in the system manual.

Set the parameters as follows:

1. Use the tables in section 2.3 to ascertain the parameters

valid for your application (amplication stage, cushioning
stage and system parameters).

2. Then set the parameters accordingly. Proceed here as

described in the chapter “Commissioning” in the system
manual (typ P.BE-SPC11-SYS...).