Compressed air tubing and screw connectors ( 4 ) – Festo Контроллер крайних положений SPC11 User Manual
Page 21
1. Installation instructions for the DNCI or DDPC
1-7
Festo P.BE-SPC11-DNCI-EN en 1208a English
Compressed air tubing and screw connectors (
4 )
See system manual type P.BE-SPC11-SYS...
•
Arrange the tubing between the valve (MPYE-5-...) and the
drive (DNCI/DDPC) symmetrically.
Recommendation: Tubing length = nominal stroke length
+ 50 mm
•
Cut the tubing and the connectors to the required length
as shown in the following table:
Horizontal or vertical mounting position
Nominal stroke
length in mm
1)
Valve type MPYE-...
Screw connectors for
Tube type
PUN
MPYE-...
DNCI/DDPC
DNCI-32-...
100 ... 400
MPYE-5-1/8-LF-010B
QS-1/8-8
QS-1/8-8
PUN-8x1.25
500
MPYE-5-1/8-HF-010B
QS-1/8-8
QS-1/8-8
PUN-8x1.25
DNCI-40-...
100 ... 250
MPYE-5-1/8-LF-010B
QS-1/8-8
QS-1/4-8
PUN-8x1.25
320 ... 500
MPYE-5-1/8-HF-010B
QS-1/8-8
QS-1/4-8
PUN-8x1.25
DNCI-50-...
100 ... 250
MPYE-5-1/8-LF-010B
QS-1/8-8
QS-1/4-8
PUN-8x1.25
320 ... 400
MPYE-5-1/8-HF-010B
QS-1/8-8
QS-1/4-8
PUN-8x1.25
500
MPYE-5-1/4-010B
QS-1/4-10
QS-1/4-10
PUN-10x1.5
DNCI-63-...
100 ... 160
MPYE-5-1/8-LF-010B
QS-1/8-8
QS-3/8-8
PUN-8x1.25
200 ... 320
MPYE-5-1/8-HF-010B
QS-1/8-8
QS-3/8-8
PUN-8x1.25
400 ... 500
MPYE-5-1/4-010B
QS-1/4-10
QS-3/8-10
PUN-10x1.5
1)
Nominal stroke lengths not listed are available upon request