1 spc11 parameters – Festo Контроллер крайних положений SPC11 User Manual
Page 31
2. Parameters of the SPC11 for the DNCI or DDPC
2-3
Festo P.BE-SPC11-DNCI-EN en 1208a English
2.1
SPC11 parameters
The SPC11 must be familiar with certain conditions of use.
These conditions of use are described by the following para-
meters, which must be entered directly on the SPC11:
Display
Parameters
Manual
Amplification stage
Influences the acceleration behaviour of the drive
Cushioning stage
Influences the run-in behaviour when moving to the end
positions and intermediate positions.
System parameters
Characteristic values for setting up the drive with reference to
the drive type
– First character: Characteristic value for the ratio of drive
and measuring system length
– Second character: Characteristic value for the ratio of drive
length and drive diameter.
Nominal stroke-
length of the drive
Nominal stroke length in 1 mm increments (e.g. nominal
stroke 300 mm: L=300), see type designation on the type
plate (for example, type DNCI-32-300-P-A has a nominal
stroke length of 300 mm).
Offset axis zero point
Offset between the end position P.01 and the axis zero point in
1 mm steps (see system manual type P.BE-SPC11-SYS-...)
Option parameters
(
Options)
Permits various options (e.g. Ready signal instead of Error
signal, Stop signal instead of P.04 etc., see system manual
P.BE-SPC11-SYS-...)
You can find the permitted settings for parameters A, C and S
for operating the SPC11 with standard cylinder type
DNCI-...-... in section 2.3. These settings are matched exactly
to the specified combinations of drives, valves and mass
loads for horizontal operation.