7 operation, 7operation – Festo Пневматический мускул MAS User Manual
Page 21

DMSP-... / MAS-...
Festo DMSP-... / MAS-... 1012d English
21
7
Operation
Please note
Extreme conditions reduce the service life
of the DMSP-... / MAS-... .
S Take into account the fact that the fol-
lowing factors can considerably reduce
the service life
C (see diagram Fig. 9):
–
increasing contracton
h and
–
additional increasing mass
m,
–
increasing ambient or operating
temperatures.
If pressure is applied to one side and ex-
hausted on the other side (rinsing), the
thermal stressing of the components can
be reduced and the service life of the
Fluidic Muscle thereby increased (not with
MAS-...-
MC.. and DMSP-...-CM).
S Check the DMSP-... / MAS-... for signs of aging at the following intervals.
Check
interval
*)
Test
Possible sign of
aging
Measure to be taken
Every 500,000
strokes
Visible Test
Clamping cracks,
blistering, other
damage to surface
Replace the DMSP-... / MAS-...
Textile fibre worn
Audible test
Air can be heard
escaping
Check pneumatic connection
Replace the DMSP-... / MAS-...
*)
The test intervals are reduced under extreme ambient conditions (e.g. strong
sunlight, high humidity, high ozone concentration).
Fig. 10
Fig. 9