Nor-Lake Capsule Pak Refrigeration Systems User Manual
Page 9
07/14 Rev. H 040086
9
Note: The process above is the same when locating/installing the insulated evaporator section of a Remote
Refrigeration System.
After the system is in place, make sure that the bolts fastening
the condensing unit section to the evaporator section are
loose enough so that the two sections can adjust to the ceiling
surfaces.
Note: On large systems, 100 series and above, the
units are placed on a rack assembly and do not have these
bolts connecting the two sections together. No adjustment is
necessary.
Note: Some motor compressors are openly spring mounted to
absorb vibration. Be sure that these bolts are loosened to permit
the compressor to float freely on the springs.
A reminder label
is applied to systems where this procedure applies.
Some systems require a permanent connection to an electrical service and a connection at the junction box located
within the condensing unit housing.
Refer to the serial tag for all pertinent electrical data. These systems must
be connected to a power supply disconnect switch and wired according to local and national electric codes. No
plumbing drain is required, under normal conditions, since the condensate moisture is dissipated automatically by
a built-in hot gas vaporizer.
g
eneRal
i
nStallation
i
nStRuCtionS