beautypg.com

Nor-Lake Capsule Pak Refrigeration Systems User Manual

Page 9

background image

07/14 Rev. H 040086

9

Note: The process above is the same when locating/installing the insulated evaporator section of a Remote

Refrigeration System.

After the system is in place, make sure that the bolts fastening

the condensing unit section to the evaporator section are

loose enough so that the two sections can adjust to the ceiling

surfaces.

Note: On large systems, 100 series and above, the

units are placed on a rack assembly and do not have these

bolts connecting the two sections together. No adjustment is

necessary.

Note: Some motor compressors are openly spring mounted to

absorb vibration. Be sure that these bolts are loosened to permit

the compressor to float freely on the springs.

A reminder label

is applied to systems where this procedure applies.

Some systems require a permanent connection to an electrical service and a connection at the junction box located

within the condensing unit housing.

Refer to the serial tag for all pertinent electrical data. These systems must

be connected to a power supply disconnect switch and wired according to local and national electric codes. No

plumbing drain is required, under normal conditions, since the condensate moisture is dissipated automatically by

a built-in hot gas vaporizer.

g

eneRal

i

nStallation

i

nStRuCtionS