beautypg.com

Models starting serial no. 0909 test setting – Alliance Laundry Systems D677I User Manual

Page 33

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Vending

31

512680

Models Starting Serial No. 0909

Test Setting

When testing coin slide operation or other

troubleshooting, set dipswitch with this shorter cycle:

1. Unplug the machine power cord.
2. Record the machine control dipswitch settings.

Then set them all to the off position. Refer to

Figure 34.

3. Plug in the machine and initiate a cycle.

NOTE: With all the control dipswitches off, the

total cycle time will be four minutes long.

4. Once all the testing is complete, unplug the

machine and re-set the dipswitches to their

original settings.

5. Plug in the machine.

Figure 34

Cool Down Per Cycle

Cool Down

Switch Number

Cycle Reset

Switch Number

(in minutes)

7

8

3 (preset at factory)

OFF

OFF

6

ON

ON

Total Cycle Time = Heat Time + Cool Down Time

Table 6

DRY2225P

DRY2225P

1 2 3 4 5 6 7 8

O
N