Vending, Meter case coin slide control, Meter case – Alliance Laundry Systems D677I User Manual

Page 29: Coin slide control

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

27

512680

Vending

Meter Case

(Metered Models)
The factory mounted coin meter case does not include

the service door lock, coin drawer, coin drawer lock

and keys. These parts must be ordered (at extra cost)

according to the purchaser’s requirements direct from

the manufacturer of your choice.

NOTE: On models with standard capacity meter

case and high capacity meter case models starting

with Serial Nos. beginning 1010, you have the

option of using a screw type lock or a 1/4 turn lock

on the meter case service door. If you choose to use

a screw lock, then the special bracket (located

inside the meter case) must be used. DO NOT use

the special bracket if a 1/4 turn lock is used. High

capacity meter case models with Serial Nos.

beginning 0910 through 1010 use 1/4 turn lock only.

Coin Drawer Security (Models with standard

capacity meter case and high capacity meter case

models starting with Serial Nos. beginning 1010 only)

– for additional security, drill out the two pilot holes

on each front side of the meter case to 1/4 or 5/16 inch

(6.4 or 8.0 mm) holes and install a bicycle lock

through these holes.

Coin Slide Control

(Coin Slide Models Only)
Power-Up Mode
When power is applied to the dryer, the control will

enter the Ready Mode. If the control was powered

down during a running a cycle, the IN USE LED will

flash once and the control will enter Start Mode. If the

dry time dipswitch settings have not been changed

from factory default, the IN USE LED will flash once.
Ready Mode
In Ready Mode, the control waits for the vend to be

satisfied before entering Start Mode.
Start Mode
In Start Mode, the vend has been satisfied, but the

Start button has not been pressed. The IN USE LED

will be lit. The timer will not count down until the

Start button is pressed.
Run Mode
In Run Mode, the control is running a cycle. The

IN USE LED is lit.

Door Open Mode
In Door Open Mode, the control turns off the heater

and motor when the door is opened during a run cycle.

The timer will continue to count down time and the

IN USE LED is lit.
End of Cycle Mode
In End of Cycle Mode, a cycle is complete and the

IN USE LED is off. The control remains in this mode

until the door is opened or additional vend has been

satisfied.
Topoffs
Any time the control receives a coin slide pulse during

a cycle it will add the programmed dry time to the time

currently remaining in the cycle. The IN USE LED

will flash briefly to indicate the coin input. The

maximum cycle time is 99 minutes. The control will

not add time beyond 99 minutes. The cool down time

will not change. If the control receives a coin slide

pulse during cool down it will exit cool down and start

heating with the cycle time equal to the programmed

time.
Temperature Selector Switch
For five minutes after the control is powered up, there

is a diagnostic feature that allows the temperature

selector switches to be tested. When the temperature

selector is changed, the new setting is displayed by

flashing the IN USE LED as follows:

High/Normal: 4 flashes
Medium/PP or Casual: 3 flashes
Low/Delicate: 2 flashes
No Heat: 1 flash