beautypg.com

A pg. 21) – American Dynamics ADCTDN0230P User Manual

Page 21

background image

21

Connecting the power cable

ADCTDN2412 (AC24 V or DC12 V)

Connect the AC 24 V or the DC 12 V power cord to the power input terminal.
To prevent connection errors or a cable disconnection, we recommend the
use of lug plates.

The following table shows the connection distances when 2-core VVF
(vinyl-insulated vinyl sheath cables) are used.

Note:

● If thin cables are used, the resistance of the cables will be high and a

significant voltage drop will occur when the camera is at its maximum
power consumption. Either use a thick cable with low resistance or place
the power supply near to the camera and shorten the length of the cable to
restrict the voltage drop at the rated current of camera to below 10 %. If
voltage drop occurs during operation, the performance will be unstable.

● Do not connect an AC 24 V cable to a commercial power supply. The

camera will be damaged. If the wrong cable is connected, the internal
circuit may be damaged. Do not use the camera. Bring it to your nearest

American Dynamics dealer for inspection.

ADCTDN0230P (AC 220 V-240 V)

Connect the power supply cable to the AC 220 V

-240 V power supply.

Note:

● When you use this camera, the socket - outlet must be installed near the

equipment to make disconnect on easily.

Video signal coaxial cable

Use either RG-59 or RG-11 coaxial cable (BNC).
Do not use other cables.

Maximum connection distance

60 m
(197 ft)

150 m
(492 ft)

240 m
(787 ft)

380 m
(1247 ft)

Conductor diameter

AWG18
(

R1.0 mm)

and more

AWG14
(

R1.6 mm)

and more

AWG12
(

R2.0 mm)

and more

AWG10
(

R2.6 mm)

and more

ADCTDN2412N_P_EN.book Page 21 Friday, September 28, 2007 12:49 PM