31

“Pipe Length on” means that the length of both pipes/components

has to be entered before every welding, “off,” that this is not

possible.

“Weather Conditions on” means that the weather has to be

Display 27

Data Recording

Pipe Length on

>Weather Cond. on

Geo-data off

selected in a list before every welding, “off,” that this is not

possible.

“Geo-data on” (only if GPS module) means that the geographic

Display 28

Data Recording

>Geo-data off

Installing Comp.on

Print Tags -M-

coodinates have to be recorded after every welding (see Sect. 6.7

for details), “off,” that this is not possible.

“Installing Company on” means that the company that performs

the installation work has to be entered before every welding,

“off,” that this is not possible.

“Print Tags – M – ” means that by pressing the MENU key, the

user can access a sub-menu for starting to print (a) label(s) with

reference to a given welding operation, with the optional label

tag printer.

All data can also be read from a bar code with the scanner, provided such a bar code
is available.

11

Self-Monitoring Functions Overview

11.1

Errors During Data Input

Code Error

An erroneous input has occurred, a code tag is poor or has an error in code symbology or code

reading was improper.

No Contact

There is no properly established electric contact between the welding unit and the fitting (check

push-on terminal on fitting), or the heater coil is defective.

Low Voltage

The input voltage is below 175 volts. Adjust generator output voltage.

Overvoltage

The input voltage is over 290 volts. Decrease generator output voltage.

Overheated

The transformer temperature is too hot. Let the welding unit cool down for about 1 hour.

System Error

CAUTION! The welding unit has to be disconnected immediately from both the
power supply and the fitting. The auto-test has detected an error in the system. The
unit must no longer be operated and has to be sent to an approved shop for check
and repair.

Temperature Error

The ambient temperature measured is outside the operating range of the welding unit, i.e.,

below – 20°C (– 4°F) or over + 60°C (+ 140°F).

Temperature Sensor Defective

The ambient temperature sensor on the welding cable is damaged or defective.

Clock Error

The internal system clock works improperly or is defective. Reset it, or send the welding unit to

the manufacturer for check and service.

Unit to Service

The recommended next service date for the welding unit is overdue. The service due message has

to be acknowledged by pressing the START/SET key. Send the welding unit to the manufacturer

or an approved service point for service and check-up.