Figure 1

Port Usage definition
Upper side port: “Inlet” as shown in figure 1 is the return line from the system
Lower side port: “Outlet (to pump)” shown in figure 1 should always be connected to the pump inlet (directly if possible to facilitate filling
of the system)
The fill-port located on top of the unit is used to fill it up with coolant, and sealed with a chrome plated brass plug.
The alternate port is also sealed with a chrome plated brass plug, and can be used as:

An alternate outlet providing a straight tube routing to a pump located underneath

To feed a second pump

To plug-in a temperature sensor

A drain


Installation

The MCRES-MICRO can be installed in any suitable location meeting its form factor requirements. For filling purposes, it is preferable to
install the MCRES-MICRO at the highest point of the liquid cooling loop. However, once filled and hermetically closed, the reservoir can
be installed practically anywhere as long as it is kept upright as shown in figure 1. Also, to facilitate the filling and bleeding operations,
you might want to wait until the circuit has been filled-up before you fasten the reservoir permanently to the chassis.

Fastening the device to the case: two mounting methods can be used

Various permanent mounts thru the reservoir ears or with the provided mounting hardware as shown page 3.
Easy mount, with the provided Velcro strips. Please note that a permanent mount is recommended for a reliable fastening of the device
over time.