beautypg.com

Cleaning – Blodgett SC-G Series User Manual

Page 15

background image

OM-SC-G 13

Cleaning

DELIMING STEPS (Use Touch Pad):

STEP 1

Press ON/OFF to turn steamer off. Open door.

STEP 2

Let cavity cool for 5 minutes or longer. While cool, wipe out cavity. Close

door.

STEP 3

Press and hold CLEAN while also turning steamer on by pressing ON/OFF,

until only DELIME and POWER lights remain on (all lights will turn on, then

off, except DELIME and POWER).

STEP 4

After 5 minutes, beeper will beep rapidly, signaling you to add Delimer/

Descaler. Door(s) must remain closed for entire delime cycle.

STEP 5

Pour 1 pint (2 cups) of delimer PER CAVITY into upper and /or lower delim-

ing port(s) and then close port(s). Press CLEAN. Double-stacked unit cavi-

ties may be delimed together or separately.

STEP 6

Delime cycle will start, taking about 30 minutes. When delime cycle is com-

plete, DELIME light will appear, DONE light will flash and beeper will beep.

STEP 7

Press ON/OFF to turn steamer off. Let cavity cool for 5 minutes or longer.

Open door, wipe out inside of cavity and wipe door gasket. Close door.

STEP 8

To use steamer, press ON/OFF. When READY light appears, steamer is ready

to use.

NOTES:

If DELIME light flashes rapidly (5 times per second), press DELIME to

restart delime cycle.

If power outage occurs during deliming, delime cycle must be re-

started. Press DELIME.

For best performance, do not interrupt delime cycle. If delime cycle

must be stopped, press ON/OFF to turn on. Set timer for 5 minutes.

After beeper beeps, press ON/OFF to turn off. Let cavity cool for 5

minutes or longer, carefully open door(s) and wipe out cavity com-

pletely.

CAUTION

NEVER LEAVE A CHLORINE SANITIZER IN

CONTACT WITH STAINLESS STEEL

SURFACES FOR LONGER THAN 30

MINUTES. LONGER CONTACT CAN

CAUSE CORROSION.

Deliming

Port