Cleaning – Blodgett SC-G Series User Manual
Page 15
OM-SC-G 13
Cleaning
DELIMING STEPS (Use Touch Pad):
STEP 1
Press ON/OFF to turn steamer off. Open door.
STEP 2
Let cavity cool for 5 minutes or longer. While cool, wipe out cavity. Close
door.
STEP 3
Press and hold CLEAN while also turning steamer on by pressing ON/OFF,
until only DELIME and POWER lights remain on (all lights will turn on, then
off, except DELIME and POWER).
STEP 4
After 5 minutes, beeper will beep rapidly, signaling you to add Delimer/
Descaler. Door(s) must remain closed for entire delime cycle.
STEP 5
Pour 1 pint (2 cups) of delimer PER CAVITY into upper and /or lower delim-
ing port(s) and then close port(s). Press CLEAN. Double-stacked unit cavi-
ties may be delimed together or separately.
STEP 6
Delime cycle will start, taking about 30 minutes. When delime cycle is com-
plete, DELIME light will appear, DONE light will flash and beeper will beep.
STEP 7
Press ON/OFF to turn steamer off. Let cavity cool for 5 minutes or longer.
Open door, wipe out inside of cavity and wipe door gasket. Close door.
STEP 8
To use steamer, press ON/OFF. When READY light appears, steamer is ready
to use.
NOTES:
•
If DELIME light flashes rapidly (5 times per second), press DELIME to
restart delime cycle.
•
If power outage occurs during deliming, delime cycle must be re-
started. Press DELIME.
•
For best performance, do not interrupt delime cycle. If delime cycle
must be stopped, press ON/OFF to turn on. Set timer for 5 minutes.
After beeper beeps, press ON/OFF to turn off. Let cavity cool for 5
minutes or longer, carefully open door(s) and wipe out cavity com-
pletely.
CAUTION
NEVER LEAVE A CHLORINE SANITIZER IN
CONTACT WITH STAINLESS STEEL
SURFACES FOR LONGER THAN 30
MINUTES. LONGER CONTACT CAN
CAUSE CORROSION.
Deliming
Port