background image

OM-DS-SC 9

OFF

DONE

ON

TIMER

Operation

Controls: Timers are located on the front right side of the unit. There are two timers

— one each for the upper and lower cavities.

The timer is used in two ways:

1. Turning the timer to any setting delivers steam to the cavity until the timer runs

down to OFF. At that time a red LED switches on and a beeper sounds and the

steam flow to the compartment stops.

2. When turned all the way to the ON position, the timer allows continuous

steaming. A green LED is turned on, and the timer does not time down. Steam

continues until the timer knob is turned to the OFF position.

1. Operating Procedure

A. Turn on the unit’s water supply.

B. Turn on electrical power to the unit.

C. Turn on the steam supply.

D. Load food into pans so that it is in uniform layers. For best results, pans

should be filled to about the same levels, and should be even on top.

E. Open the door and slide the pans onto the supports. If you will only be

steaming one pan, put it in the middle rack position.

F. Close the door.

NOTE: The door must be closed before steam will enter the cavity. If the

door is opened when the timer is on, the steam will stop.

G. Turn the timer to one of the following settings:

1. If you want to steam for a definite period of time, set the timer to

that time. Steam will be delivered to the cavity for that time, and

then stop. A buzzer and red LED will indicate that the timed cycle is

complete. Steam flow stops.

2. If you want to steam continuously, turn the timer to the ON position.

A green light will come on. Steam will be delivered to the cavity until

the timer is returned to OFF.

H. Open the door.

I.

Using a pad or oven mitt to protect your hands, remove the pans from the

steamer.

J. To shut down the unit, turn the Timer to the OFF position.

WARNING

ANY POTENTIAL USER OF THE EQUIPMENT

SHOULD BE TRAINED IN SAFE AND CORRECT

OPERATING PROCEDURES.

WARNING

WHEN YOU OPEN THE DOOR, STAY AWAY

FROM THE STEAM COMING OUT OF THE

UNIT. THE STEAM CAN CAUSE BURNS.

Timer Controls for each of the two

cavities are identical.