Data bits: 8, Parity: none, Stop bits: 1 – Allied Telesis AT-CM70S User Manual
Page 78

Chapter 2: Installation
78
Cabling a RS-232
Console Port
(AT-CM70S Line
Card Only)
When connecting to the RS-232 console port on the front of the
AT-CM70S line card, observe the following guidelines:
Once the connection is done, set the terminal or terminal emulation
program to the following defaults:
Baud rate: 115200 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The settings are for a DEC VT100 or ANSI terminal, or an equivalent
terminal emulation program.
To connect to the RS-232 console port on the AT-CM70S line card,
perform the following procedure:
1. Connect the 8-pin Mini-DIN end of the RS-232 serial cable to the
console port on the front of the AT-CM70S line card, as shown in
Figure 31.
Figure 35. Connecting a Management Cable to the Console Port on an
AT-CM70S Line Card
2. Connect the other end of the cable to an RS-232 port on a terminal or
a personal computer with a terminal emulation program.
3. Power ON the end-nodes.
When the connection is established and the console port is operational,
the CONSOLE LED for the console port should show green.
F
P
CPU RESET
C
O
N
S
O
L
E
L/A FD 100
2
AIS 1
2
4
3
LOTC
NML
1
RCL
NML
T
X
RDY
910