beautypg.com

Port poe led is not solid green – Allied Telesis AT-GS950/8POE User Manual

Page 58

background image

Chapter 4: Troubleshooting

58

Port PoE LED is not Solid Green

On those ports that are supplying PoE power to another device, verify that
the port PoE LED is solid green. If the LED is not solid green, do the
following:

ˆ

Verify that the connected device is no more than 100 feet from the
switch.

ˆ

If the port PoE LED is solid amber, then the power required by the
connected device is more than the maximum power budget for the
port. If this is the case, the connected device may not qualify for
connection to the switch.

ˆ

If the port PoE LED is blinking amber, then the overall power budget of
the switch was exceeded when the powered device was connected.
Re-evaluate the overall power requirements of all the powered devices
connected to the switch to assure that the overall power budge is not
exceeded. This may mean that more than one switch is required to
supply the PoE power required by the PoE powered devices on the
network.

Note

A 1000Base-T connection may require five to ten seconds to
establish a link.