beautypg.com

Cable specifications, Table 9. twisted pair cabling and distances – Allied Telesis AT-x230-18GP User Manual

Page 47

background image

AT-x230-10GP and AT-x230-18GP Switches Installation Guide

37

Cable specifications

Table 9 contains the cable specifications for the twisted pair ports.

Note

The twisted pair ports on the switch feature auto-MDI when
operating at 10, 100, or 1000 Mbps. A port is configured as MDI or
MDIX when it is connected to an end node. Consequently, you can
use a straight-through twisted pair cable when connecting any type
of network device to a port on the switch.

T

ABLE

9. T

WISTED

PAIR

CABLING

AND

DISTANCES

Speed

Type of cable

Maximum

operating

distance

10 Mbps

Standard TIA/EIA 568-B-compliant
Category 3 or better shielded or
unshielded cabling with 100 ohm
impedance and a frequency of 16
MHz.

100 m (328 ft)

100 Mbps

Standard TIA/EIA 568-A-compliant
Category 5 or TIA/EIA 568-B-
compliant Enhanced Category 5
(Cat 5e) shielded or unshielded
cabling with 100 ohm impedance
and a frequency of 100 MHz.

100 m (328 ft)

1000 Mbps

Standard TIA/EIA 568-A-compliant
Category 5 or TIA/EIA 568-B-
compliant Enhanced Category 5
(Cat 5e) shielded or unshielded
cabling with 100 ohm impedance
and a frequency of 100 MHz.

100 m (328 ft)

This manual is related to the following products: