beautypg.com

2 nr01 construction – Campbell Scientific NR01 Net Radiometer User Manual

Page 8

background image

NR01 Four-Component Net Radiation Sensor

The following equations assume the temperature is in Kelvin.
Add 273.15 to equations 2.1-9 and 2.1-10 for temperature in
degree Celsius.

NOTE

T

surface

= (LW

out

/5.67.10

-8

)

1/4

2.1-9

T

sky

= (LW

in

/5.67.10

-8

)

1/4

2.1-10

2.2 NR01 Construction

FIGURE 2.2-1. The NR01 Four-Component Net Radiation Sensor

(1) SW

in

solar radiation sensor or pyranometer,

(2) LW

in

Far Infrared radiation sensor or pyrgeometer

(3) radiation shield
(4) leveling assembly for x- and y axis, block plus bolts for x-axis
adjustment
(5) leveling assembly for x- and y axis, horizontal rod
(6) connection body containing the Pt100 temperature sensor, heater,
and hole for user-supplied temperature sensor (add cable gland M8)
(7) LW

out

Far Infrared radiation sensor or pyrgeometer

(8) leveling assembly for x- and y-axis, bolts for y-axis adjustment
(9) SW

out

solar radiation sensor or pyranometer

A level is located under the radiation screens.