Campbell Scientific NR01 Net Radiometer User Manual
Page 32
![background image](/manuals/416006/32/background.png)
NR01 Four-Component Net Radiation Sensor
Avg
Albedo
Avg Total Net radiation
Avg temperature corrected IR01 Up
Avg temperature corrected IR01 Down
;{CR23X}
;Program Example 3 for CR23X datalogger
;
;*Table 1 Program
01: 2
Execution
Interval
(seconds)
;Measure all four sensor elements with one instruction, use auto-ranging for best resolution
1: Volt (Diff) (P2)
1: 4
Reps
2: 30
Auto, 50 Hz Reject, Slow Range (OS>1.06)
3: 1*
DIFF
Channel
4: 1
Loc [ SR01_up ]
5: 1.0
Multiplier
6: 0.0
Offset
;Apply the individual calibration factors to each component
;with one scaling instruction
;Typical data on the data sheet might be
;Sensor
Sensitivity
uV/W/m^2
;Pyranometer UP SR01
15.35
;Pyranometer DOWN SR01
13.30
;Pyrgeometer UP IR01
8.5
;Pyrgeometer DOWN IR01
8.2
; Multipliers calculated at 1000/sensitivity
2: Scaling Array (A*Loc+B) (P53)
1: 1
Start Loc [ SR01_up ]
2: 65.146 A1
;SR01 up
3: 0
B1
4: 75.18
A2
;SR01 down
5: 0.0
B2
6: 117.65 A3
;IR01 up
7: 0.0
B3
8: 121.95 A4
;IR01 down
9: 0.0
B4
;Measure NR01 temperature
3: Full Bridge w/mv Excit (P9)
1: 1
Reps
2: 32**
50 mV, 50 Hz Reject, Slow, Ex Range
3: 32**
50 mV, 50 Hz Reject, Slow, Br Range
4: 5*
DIFF
Channel
5: 1
Excite all reps w/Exchan 1
6: 4200*** mV
Excitation
7: 5*
Loc [ Temp_C ]
8: 1
Mult
9: 0
Offset
28