Campbell Scientific NR01 Net Radiometer User Manual
Page 34
![background image](/manuals/416006/34/background.png)
NR01 Four-Component Net Radiation Sensor
; IR01_upCor = IR01_up+5.67 10-8 Temp_K4
; IR01_dnCor = IR01_dn+5.67 10-8 Temp_K4
12: Z=F (P30)
1: 5.67
F
2: -8
Exponent
of
10
3: 25
Z Loc [ scratch_1 ]
13: Z=F (P30)
1: 4
F
2: 0
Exponent
of
10
3: 26
Z Loc [ scratch_2 ]
14: Z=X^Y (P47)
1: 6
X Loc [ Temp_K ]
2: 26
Y Loc [ scratch_2 ]
3: 27
Z Loc [ scratch_3 ]
15: Z=X*Y (P36)
1: 25
X Loc [ scratch_1 ]
2: 27
Y Loc [ scratch_3 ]
3: 28
Z Loc [ scratch_4 ]
16: Z=X+Y (P33)
1: 3
X Loc [ IR01_up ]
2: 28
Y Loc [ scratch_4 ]
3: 11
Z Loc [ IR01_upCor ]
17: Z=X+Y (P33)
1: 4
X Loc [ IR01_dn ]
2: 28
Y Loc [ scratch_4 ]
3: 12
Z Loc [ IR01_dnCor ]
;
;Output data to final storage every 60 minutes
18: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 60
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
19: Real Time (P77)
1: 0220
Day,Hour/Minute (midnight = 2400)
20: Average (P71)
1: 12
Reps
2: 1
Loc [ SR01_dn ]
Note: Proper entries will vary with program and *input channel usage. For other loggers use:
** 25 mV range for CR10X, 50 mV for 21X and CR7
*** 4200 mV for 21X and CR7, 2100 mV for CR10X
30