Campbell Scientific NR01 Net Radiometer User Manual
Page 33
![background image](/manuals/416006/33/background.png)
NR01 Four-Component Net Radiation Sensor
4: Temperature RTD (P16)
1: 1
Reps
2: 5
R/R0 Loc [ Temp_C ]
3: 5
Loc [ Temp_C ]
4: 1.0
Mult
5: 0
Offset
5: Z=X+F (P34)
1: 5
X Loc [ Temp_C ]
2: 273.18 F
3: 6
Z Loc [ Temp_K ]
;Net SR01 shortwave radiation = SR01 Up - SR01 Down
6: Z=X-Y (P35)
1: 1
X Loc [ SR01_up ]
2: 2
Y Loc [ SR01_dn ]
3: 7
Z Loc [ Net_Rs ]
;Net IR01 longwave radiation = IR01 Up - IR01 Down
7: Z=X-Y (P35)
1: 3
X Loc [ IR01_up ]
2: 4
Y Loc [ IR01_dn ]
3: 8
Z Loc [ Net_Rl ]
;Albedo = SR01 Down / SR01 Up
8: Z=X/Y (P38)
1: 2
X Loc [ SR01_dn ]
2: 1
Y Loc [ SR01_up ]
3: 9
Z Loc [ Albedo ]
;Net total radiation = (SR01 Up + IR01 Up) - (SR01 Down + IR01 Down)
9: Z=X+Y (P33)
1: 1
X Loc [ SR01_up ]
2: 3
Y Loc [ IR01_up ]
3: 23
Z Loc [ Up_total ]
10: Z=X+Y (P33)
1: 2
X Loc [ SR01_dn ]
2: 4
Y Loc [ IR01_dn ]
3: 24
Z Loc [ Dn_total ]
11: Z=X-Y (P35)
1: 23
X Loc [ Up_total ]
2: 24
Y Loc [ Dn_total ]
3: 10
Z Loc [ Net_total ]
;Correct IR01 Up and IR01 Down for temperature
29