NR01 Four-Component Net Radiation Sensor

4: Temperature RTD (P16)
1: 1

Reps

2: 5

R/R0 Loc [ Temp_C ]

3: 5

Loc [ Temp_C ]

4: 1.0

Mult

5: 0

Offset


5: Z=X+F (P34)
1: 5

X Loc [ Temp_C ]

2: 273.18 F
3: 6

Z Loc [ Temp_K ]


;Net SR01 shortwave radiation = SR01 Up - SR01 Down

6: Z=X-Y (P35)
1: 1

X Loc [ SR01_up ]

2: 2

Y Loc [ SR01_dn ]

3: 7

Z Loc [ Net_Rs ]


;Net IR01 longwave radiation = IR01 Up - IR01 Down

7: Z=X-Y (P35)
1: 3

X Loc [ IR01_up ]

2: 4

Y Loc [ IR01_dn ]

3: 8

Z Loc [ Net_Rl ]


;Albedo = SR01 Down / SR01 Up

8: Z=X/Y (P38)
1: 2

X Loc [ SR01_dn ]

2: 1

Y Loc [ SR01_up ]

3: 9

Z Loc [ Albedo ]


;Net total radiation = (SR01 Up + IR01 Up) - (SR01 Down + IR01 Down)

9: Z=X+Y (P33)
1: 1

X Loc [ SR01_up ]

2: 3

Y Loc [ IR01_up ]

3: 23

Z Loc [ Up_total ]


10: Z=X+Y (P33)
1: 2

X Loc [ SR01_dn ]

2: 4

Y Loc [ IR01_dn ]

3: 24

Z Loc [ Dn_total ]


11: Z=X-Y (P35)
1: 23

X Loc [ Up_total ]

2: 24

Y Loc [ Dn_total ]

3: 10

Z Loc [ Net_total ]


;Correct IR01 Up and IR01 Down for temperature