beautypg.com

2 sr01 pyranometer specifications – Campbell Scientific NR01 Net Radiometer User Manual

Page 16

background image

NR01 Four-Component Net Radiation Sensor

3.2 SR01 Pyranometer Specifications

TABLE 3.2-1. Specifications of SR01

SR01 ISO / WMO Specifications
Overall classification
according to ISO 9060 /
WMO

Second class pyranometer

Response time for 95 %
response

18 s

Zero offset a (response to
200 W/m

2

net thermal

radiation)

< 15 W/m

2

Zero offset b (response to 5
k/h change in ambient
temperature)

<4 W/m

2

Non-stability

< 1% change per year

Non-Linearity

< +/- 2.5%

Directional response for
beam radiation:

Within +/- 25 W/m

2

Spectral selectivity

+/- 5% (305 to 2000 nm)

Temperature response
(within an interval of 50
degrees C)

Within 6% (-10 to +40 degrees C)

Tilt response

Within +/- 2%

SR01 Additional Measurement Specifications
Sensitivity

10-40 μV/Wm

-2

Expected voltage output

Application with natural solar radiation: 0.1 to +
50 mV

Sensor resistance

Between 40 and 60 Ohms (without trimming)

Power required

Zero (passive sensor)

Range

To 2000 Wm

-2

Spectral range

305 to 2800 nm (50% transmission points)

Required programming

Φ = U / E

Expected accuracy for daily
sums

+/- 10%

Calibration

Calibration traceability

To WRR, procedure according to ISO 9847

12