LoggerLink Settings

The following settings for LoggerLink can be viewed and/or set

from your device's Settings screen. Tap on LoggerLink under

Apps to display and change the settings.

Auto-Lock Settings: Prevent Auto-Lock

The Prevent Auto-Lock setting will prevent your device

from going to sleep when connected to a datalogger.

PakBus Settings: Global Address

The PakBus address for this device. Each device in a

PakBus network must have a unique address. Valid PakBus

addresses are 1 through 4094. Typically, software such as

LoggerLink should use a value greater than 3999. This is

because, when a neighbor filter is set up, a PakBus

datalogger will answer a Hello message from any device

with an ID greater than 3999, but will ignore devices with

IDs less than 4000 that are not in their neighbor list.

Troubleshooting: Logging Enabled

Enabling logging will create a low level log file of all

communications with a datalogger. Note that enabling

logging will slow down LoggerLink. Logging should only

be enabled, if you are experiencing communication

problems.
You can use the

off-line file

system to email a log file to

your computer. If you cannot email the log file, iTunes is

required to copy log files to your computer to be viewed.