beautypg.com

Troubleshooting tools and tips – Campbell Scientific 9522B Iridium Satellite Modem and COM9522B Interface Modem User Manual

Page 29

background image

9522B Iridium Satellite Modem and COM9522B Interface Modem

7. Troubleshooting Tools and Tips

Problem: I have intermittent successful connections between the remote and

base station modem. The signal strength is weak and the data transfer speeds

are slow.

Solution: The antenna may not have a complete 180° view of the sky. Some

objects and debris such as snow and trees can interfere with communications.

Make sure there are no obstructions to the antennas when installing. You may

need to reposition or elevate your antenna to obtain the best reception.

The Signal Quality AT command can be used to confirm signal strength during

installation/repositioning of the antenna. This will require use of a laptop

connected to the COM9522B interface and a terminal emulator. Once the

terminal emulator is connected, the following command can be entered to

check signal strength:

AT+CSQ

The modem should return a value of between 0 and 5 within 10 seconds.

Attempt to get the largest value during your installation/repositioning.

Problem: LoggerNet immediately brings back an error message saying that

communications with the station have failed.

Solution: Sometimes PakBus© beacons sent to other stations by LoggerNet

interfere with successful communications using Iridium Satellite Modems.

Either turn PakBus© beaconing off or disable communications with your other

stations when you attempt to download using Iridium. This can be

accomplished in the Setup screen in LoggerNet. Finally, restart LoggerNet to

clear the communications queue of any tasks.

Problem: LoggerNet makes several attempts to connect to the remote station

with no success. The failure is not immediate and the LoggerNet LogTool may

show a “No Carrier Detected” error.

Solution: It is possible that the base modem has lost its configuration. Resend

the configuration as shown in Section 3.2, Setup of Iridium Modems, and

attempt communications again.

Problem: I am using Iridium to communicate through the CS I/O port on my

datalogger. Whenever I try connecting with the datalogger, LoggerNet reports

that communication with the station has failed. This message takes several

seconds to appear.

Solution: You may have connected your SC932A device backwards at the

remote station. When you install the SC932A, it is imperative to make sure

that the device is connected in the proper way. Follow the label on the device

for the proper connections.

21