Datalogger configuration, 1. device configuration utility – Campbell Scientific 9522B Iridium Satellite Modem and COM9522B Interface Modem User Manual
Page 18

9522B Iridium Satellite Modem and COM9522B Interface Modem
This is a summary of the currently active modem profile and ensures that when
power is cycled to the modem it will have the correct auto-answer, DTR, and
flow control settings. Exit Hyperterminal and save your settings for later.
4. Datalogger Configuration
To ensure proper communications with the datalogger, it will be necessary to
configure the datalogger. This can be done via DevConfig. Follow the
instructions provided to make a connection to the datalogger.
FIGURE 4-1. Device Configuration Utility
Once connected, select the
ComPorts Settings tab (FIGURE 4-2). With the
ComPort set to RS-232, set the Verify Interval to its maximum value of
65534 seconds and select the 19.2K Fixed Baud Rate. If you require the use
of the CS I/O port for communications, select the
CSI/O – ME ComPort and
set the
Baud Rate to 19.2K Fixed. If you require the use of a COM port for
communications, select the appropriate
COMPort and set the Baud Rate to
19.2K Fixed.
Make any additional changes required for your application. Press the
Apply
button to save the changes.