DSR Installer/User Guide

Appendix C: Using DSRIQ-SRL Modules

The DSRIQ-SRL module is a serial-to-VGA converter which permits VT100-

capable devices to be viewed from the DSR switch local port or by using

the DSView software. The actual serial data is not accessed, but is merely

displayed. All serial data coming from the target device is displayed in a VT100

window, placed into a video buffer and sent to the DSR appliance as though it

came from a VGA server. Likewise, keystrokes entered on a keyboard are sent

to the attached device as though they were typed upon a VT100 terminal.

DSRIQ-SRL module modes

The following modes can be accessed from the DSRIQ-SRL module:

On-Line - This mode enables you to send and receive serial data.

History - This mode enables you to review serial data.

Confi guration - This mode enables you to specify DSR switch communica-
tion parameters, the appearance of the Terminal Applications menu and
key combinations for specifi c actions and macros.

Configuring the DSRIQ-SRL module

NOTE: The DSRIQ-SRL module is a DCE device and only supports VT100 terminal emulation.

Pressing CTRL-F8 will activate the Configuration Screen, which contains menu

items that allow you to configure your DSRIQ-SRL module.

NOTE: When the Confi guration Screen is active, pressing Enter saves changes and returns you
to the previous screen. Pressing Esc returns you to the previous screen without saving changes.

Within the Configuration Screen, you can modify the following options:

Baud Rate - This option allows you to specify the serial port communica-
tions speed in bauds per second (BPS). Available options are 300, 1200,
2400, 9600, 19200, 34800, 57600 or 115200. The default value is 9600.

Parity - This option allows you to specify the serial port communications
parity. Available options are EVEN, ODD or NONE. The default value
is NONE.

Flow Control - This option allows you to specify the type of serial fl ow
control. Available options are NONE, XOn/XOff (software) and RTS/CTS
(hardware). The default value is NONE. If you select a baud rate of 115200,