INCORRECT FORMAT


Possible causes for this problem are:
• Incorrect Format Number - the current Check data format in the MICRSafe is not the desired

format. Use the “Configure” option within MICRbase to verify/change the format.

• Incorrect Message Format - the current Message format in the MICRSafe is not the desired

format. Use the “Configure” option within MICRbase to verify/change the Message format.


Determine if any of the conditions described above are true:
◊ If yes, rectify and continue to step 02.
◊ If no, continue to step 18.


09

PATH IS OBSTRUCTED


Foreign debris is obstructing the check path:
• Loose debris - power off the MICRSafe and try to push out any loose debris on the check

path. Grab a cleaning card and force it through the check path (this is a manual process, the
motor will not turn on). Try this procedure several times until the debris comes out. Power
on the MICR Reader.

• Wedged debris - the debris is wedged in and cannot be removed with the procedure described

above.


Is the foreign debris removable?
◊ If yes, remove and continue to step 02.
◊ If no, continue to step 18.