beautypg.com

Send data after error, Send status after data – MagTek MICRSafe99875466 User Manual

Page 21

background image

Section 4. Legacy Commands

13

Comm Mode 7, also known as Packet Mode, calculates an LRC (Longitudinal
Redundancy Check), and appends it to the data message. Also, if a (hex 15)
character is received in this mode, the MICRSafe will resend the last message.

Send Data After Error

The Send Data After Error option specifies whether the MICRSafe will return data to the
Host after a read error. If YES is selected and the MICRSafe detects a read error, the
MICRSafe will still send the data back to the Host. If NO is selected and the MICRSafe
finds an error, it will discard the data and nothing will be sent. The error conditions are
listed in Table 4-4.

Send Status After Data

The Send Status After Data option causes the MICRSafe to append a two-digit
error/status code to the end of the MICR data. For most formats (See Appendix A), the
error/status code will always be preceded by a forward slash (/). The error/status codes
are listed in Table 4-4.

For example, if a Canadian check (code 08) is read and has no errors, and the MICR data
is “1234567890”, then the message from the MICRSafe will look like this:

MICR Data: 1234567890/08

The status code is always at the end of the data, not the end of the message. For example,
using the above conditions, with the message format set to send and , the
message from the MICRSafe will look like this:

MICR Data: 1234567890/08

Table 4-4. Error and Status Codes

PRIORITY

CODE

TYPE

DESCRIPTION

9

01

Error

No MICR data: no transit and no account found

8

09

Status

Mexican check

7

08

Status

Canadian check

6

05

Error

Transit error: No transit, bad character, bad
length, bad check digit

5

07

Error

Account error: No account, bad character

4

04

Error

Check # error: Bad character in check number

4

04

Status

No check number

3

03

Status

Low MICR signal, good read

2

10

Status

Business check

1

11

Status

Amount field present

0

00

Status

Good read

Notes:

The LED indicator will turn red on all error conditions.

The absence of a check number is not considered an error.