beautypg.com

MagTek MICRSafe99875466 User Manual

Page 54

background image

MICRSafe with 3-Track MSR

46



Fmt 0800: [transit] [acct #]

[transit]:

- all characters in the field

- keep dashes


[acct #]:

- all characters are sent

- remove spaces and dashes


Fmt 1100:

[transit] 'T' [acct #] 'A' [check #]


[transit]:

- all characters in the field

- keep dashes


[acct #]:

- all characters are sent

- remove spaces and dashes


[check #]:

- all characters in the field


Fmt 1200:

[transit] 'T' [acct #] 'A' [check #]


[transit]:

- all characters in the field

- keep dashes


[acct #]:

- all characters are sent

- remove spaces and dashes


[check #]:

- always 6 characters, zero filled


Fmt 2400:

[transit] 'T' [acct #] 'A' [check #] 'C' [amount] '$'


[transit]:

- all characters in the field

- keep dashes


[acct #]:

- all characters are sent

- remove spaces and dashes


[check #]:

- always 6 characters, zero filled


[amount]:

- all characters in the field





Fmt 3100:

[transit] '/' [acct #] '/' [check #]

[transit]:

- all characters in the field

- remove dashes


[acct #]:

- all characters are sent

- remove spaces and dashes

[check #]:

- maximum of 10 digits

- remove spaces and dashes

- if no check number, remove preceding slash ('/')


Fmt 3800:

'T' [transit] 'A' [acct #] 'C' [check #]


[transit]:

- all characters in the field

- keep dashes

[acct #]:

- all characters are sent

- include leading characters