12/10/07 Model LE10A Text

24

8.1 Minor trouble shooting

Symptom

Probable Cause

Corrective Action

Hydraulic pump motor

does not run even

though hydraulic on

button is depressed.

a. Power line disconnected

b. Circuit protector OFF

c. Thermal relay activated

d. Loose terminal retaining

screw

e. Out-of-stock limit switch

activated

a. Connect

b. Turn ON

c. Push reset button

d. Tighten

e. Set vise clamp selector at

Saw blade motor does

not run even when

blade drive button is

depressed.

a. Terminal relay activated

b. Vise clamp selector set at

c. Rear vice stop position

switch

set at

a. Push reset button

b. Set vice clamp selector at

c. Move rear vise to its

forward limit position

(when performing bundle

cutting)

d. Set rear vise stop position

switch at

(when

performing single cutting)

Rear vice does not

move forward or

backward even when

its forward or

backward button is

depressed.

a. Auto-Manual selector set at

b. Saw head not at its UP

position

a. Set auto-manual selector

b. Raise saw head to its UP

position

Front or rear vise does

not open or close even

though vise clamp

selector is manipulated

a. Auto-Manual selector set at

a. Change auto-Manual

selector setting.

For problems not indicated on the above chart, refer to the electrical circuit and

hydraulic circuit diagrams (provided inside the electrical enclosure).

For original Dake replacement parts contact us at:

DAKE Division of JSJ

724 Robbins Road

Grand Haven, MI 49417

Phone: 1-800-937-3253 616-842-7110

Fax: 1-800-846-3253

616-842-0859

E-mail:

[email protected]