Dake Model LE10A User Manual
Page 24

12/10/07 Model LE10A Text
24
8.1 Minor trouble shooting
Symptom
Probable Cause
Corrective Action
Hydraulic pump motor
does not run even
though hydraulic on
button is depressed.
a. Power line disconnected
b. Circuit protector OFF
c. Thermal relay activated
d. Loose terminal retaining
screw
e. Out-of-stock limit switch
activated
a. Connect
b. Turn ON
c. Push reset button
d. Tighten
e. Set vise clamp selector at
Saw blade motor does
not run even when
blade drive button is
depressed.
a. Terminal relay activated
b. Vise clamp selector set at
c. Rear vice stop position
switch
set at
a. Push reset button
b. Set vice clamp selector at
c. Move rear vise to its
forward limit position
(when performing bundle
cutting)
d. Set rear vise stop position
switch at
(when
performing single cutting)
Rear vice does not
move forward or
backward even when
its forward or
backward button is
depressed.
a. Auto-Manual selector set at
b. Saw head not at its UP
position
a. Set auto-manual selector
b. Raise saw head to its UP
position
Front or rear vise does
not open or close even
though vise clamp
selector is manipulated
a. Auto-Manual selector set at
a. Change auto-Manual
selector setting.
For problems not indicated on the above chart, refer to the electrical circuit and
hydraulic circuit diagrams (provided inside the electrical enclosure).
For original Dake replacement parts contact us at:
DAKE Division of JSJ
724 Robbins Road
Grand Haven, MI 49417
Phone: 1-800-937-3253 616-842-7110
Fax: 1-800-846-3253
616-842-0859
E-mail:
Web: