Dake Model LE10A User Manual
Page 10
12/10/07 Model LE10A Text
10
CAUTION!!!!!
THE GROUND WIRE MUST BE CONNECTED; FAILURE TO CONNECT THE
GROUND WIRE CAN DAMAGE THE MACHINE AND VOID THE WARRANTY.
Next, make sure the emergency stop button is not activated and that item 4 on
page 11 is to the right. Now press the LIFT button (see picture item 6 on page 11);
lifting starts in one or two seconds after the emergency button is released, the head
continues in the up direction as long as the button is held down.
If the head does
not go up, immediately turn the power off, consult your electrician.
3.3 Inspections for Trial Run
After the saw has been installed, this inspection should be performed. The following
checklist will locate any items that may need further attention.
Connect the power (only a qualified electrician)
Coolant fluid is full (only water based coolant)
Hydraulic oil level is full
Check for loose components, guards or panels
Tools and other materials left on saw, remove all tools that are not
part of the machine.
3.4 Environment Requirement
1. Keep the machine on a dry, shaded place to prevent damage to the electrical
components.
2. Storage condition:
Temperature: -20
°
C
75°
C
Humidity: 10% 90%
3. Operation condition:
Temperature: 0
°
C
55°
C
Humidity: 10% 90%
3.5 Dismantle
1.
Turn the power OFF.
2.
Disconnect the power supply.
3.
Drain the hydraulic oil and coolant.
4.
Reverse the procedure of installation for this machine.