Dake Model LE10A User Manual
Page 12
12/10/07 Model LE10A Text
12
4. AUTO-MANUAL SELECTOR
For Continuous cutting, turn this selector to
To individually operate each function, turn this selector to the hand picture
(MANUAL)
.
5. QUICK APPROACH BUTTON
When this button is pressed the head will move in the downward position until the
quick approach arm touches the material.
6. RAISE BUTTON
When this button is pressed the blade motor stops and the saw head moves in the
upward position. When the button is released the head will stop moving.
7. VISE CLAMP BUTTON
When this button is pressed and held, one vise will open and the other vise will
close
8. VISE CLAMP SELECTION
When this selector is turned to the left (see picture to the right) with the auto-
manual selector (4) turned to MANUAL the front vise opens and the rear vise
closes; when the selector is turned to the picture (on the lower left of this
paragraph) the rear vise opens and the front vise closes.
NOTE:
On the manual operation, if this selector is
Not turned to the “Rear vice open” the saw blade motor will not operate even if the
drive button (3) is depressed.
9 & 10 REAR VISE FORWARD AND BACKWARD BUTTONS
When the forward button (9) is depressed with the auto-manual selector turned to
“MANUAL” the rear vise moves forward; when the backward button (10) is
depressed, the rear vise moves backward. The rear vise stops moving when the
button is released.
11. CUTTING FLUID PUMP SWITCH
When this switch is set at “|” the cutting fluid pump operates and the cutting fluid will
be on even though the saw blade motor is not in operation. Use this switch when
removing saw chips with the cutting fluid (without the blade operation).
12. CUTTING PIECE COUNTER
This counter is used to press the number of cuts required on the automatic
operation. When the counter reaches the preset number, the machine automatically
stops. To activate the counter, set the counter ON/OFF witch at “| “
13. REAR VISE STOP POSITION SWITCH
(AUTO)
.
Front vise
opens
Rear vise
opens